Maximum temperature allowed for hydraulic air coolers

When the heat-dissipating core of the hydraulic air cooler is a plate-fin type aluminum alloy material, the maximum temperature of the fluid allowed to pass can be as high as 140 ° C, and the performance and service life of the core are not affected when operating at this temperature. However, considering the cooling fan  in the cooler, on the one hand, the high-temperature air (suction type) is blown to the fan for a long time; on the other hand, the core  transmits and radiates heat to the fan directly. In such an environment, the service life of a cooling fan that is not resistant to high temperatures is greatly affected. For the above reasons, Chance hydraulic oil coolers are generally recommend a fluid with a maximum service temperature of less than 120 °C. When the temperature used exceeds 140 °C, please contact with us for further solution.